Demo helper GRI Catalog Admin · Admin wireframes (spec ii) Page 8 of 12 · Data entry · unsupported answer format Invented data · Bluefin Foods Group (fictional tenant)

FY2025 GRI report · Bluefin Processing TH

Bluefin Foods Group / Processing / Thailand · FY2025 (Jan 2025 - Dec 2025). One question of the cycle, opened for entry. The answer format is not supported by this app version.
cycle active methodology lock provisional
GRI 302-3 (a) Energy used per unit of production, and the basis of the ratio Answer format not supported by this app version Required by this edition Omission also refused here cannot be shown
Composed guidance (placeholder) Give the energy figure per unit of production for the site and say what the denominator is, so the ratio can be read without guessing what it was divided by.
Enter an answer Report an omission instead

This question cannot be shown here yet

This question uses an answer format this version of the app cannot display yet. Your data is safe. Contact your administrator.

What happened
The standard edition this cycle uses asks for this answer in a format added after this version of the app was built.
What it means for your data
Nothing is changed, hidden, or deleted. No answer and no omission has been removed. Every other question in this cycle works normally.
Why you see this instead of a box to type in
A guessed input would take a figure into the wrong kind of answer, and the question would read as answered when it is not. Refusing is the safe outcome; a wrong control is not.
What to do next
Send the details beside this panel to your workspace administrator. The app needs an update first; nothing you can do on this screen will make the format work.
Tell your administratorGRI 302-3 (a)the question code
Reporting cycleFY2025 GRI report
Organization unitBluefin Processing TH
Problem reportedVOCAB_TYPE_INVALIDdeclared format valueDenominatorMatrix, unknown here
Other questions here are unaffected
GRI 302-1 (a) · Energy used at this site, by sourceanswered
GRI 302-2 (a) · Energy used outside the site, by sourcenot answered yet
GRI 302-3 (a) · Energy used per unit of production, and the basis of the ratiocannot be shown
One or the other, never both, and neither one here. A question holds either an answer or an omission, never both at once, and switching between them clears the other. Neither can be recorded on this question while the format is unsupported, so both choices above are switched off rather than left to fail on save.
Back to the question list Save answer
Question and cycle details the standard edition this question comes from, its declared answer format, and where this question sits in the reporting cycle Show details
Layout · the PM's part 1 ruling R2-6The four entry pages share one layout, and this refusal page keeps it. Before this pass the question reference card and the cycle context card filled the whole first screen and the refusal panel started below the fold, which on this page of all pages is the wrong order: the reason a person came here is the panel telling them what to do. The facts they need without opening anything sit in the question strip under the page header, including the two that matter here, that the answer format is not supported and that the omission route is refused too. Everything else moved into the collapsed "Question and cycle details" section under the refusal area, and the state gallery below draws that section OPEN so the review can confirm every row of both former cards survived. The alternatives the PM offered were a card on the right and a card below. The right-hand card was rejected because it takes width the table answer on page 6 of this wireframe set needs and because this page already uses its right column for the "tell your administrator" block. A plain card below was rejected because it keeps reference detail permanently in the scroll. One thing to note for the review: the strip carries the SHORT form of the refusal, and the panel carries the full explanation, so the same fact appears twice by design rather than by accident.
Annotation · not proposed UIFail-closed contract (spec ii 3.9). The input vocabulary is ONE exported constant shared by the import validator, the entry validator, and the catalog reads that feed this screen. Native paths refuse an unknown answer format with 422 VOCAB_TYPE_INVALID on WRITE, READ, IMPORT, and RENDER. The renderer receives the declared format from the catalog read and, when it does not recognize it, shows this explicit error state: never a numeric fallback, never a blank control, never a text box that happens to accept anything. Test 9.2 names the UI unsupported-type state and the never-a-numeric-fallback rule as an acceptance case, so this drawing is the reviewable form of a tested requirement.
Annotation · not proposed UIWhy guessing a format is forbidden, stated as a mechanism rather than a preference. The answer payload is a CLOSED set with exactly one legal slot per format (spec ii 3.9): the legacy formats and date write value, while table and written answers write structuredValue. A guessed control picks a slot. Two outcomes follow, both bad: the write is refused anyway and the user has wasted the work with no explanation, or the value lands in a slot that means something different from what the question asked, and the question reads as answered. Since the same clause also drives later reporting, a wrong-slot value propagates into anything built on it. Refusing at render is the only outcome that leaves the record honest.
Annotation · not proposed UIHow this state is REACHED, in plain terms for the review: the catalog is versioned and published independently of the app, so a published edition can declare a format that a deployed app version predates. It is not a data fault and not a user fault, which is why the copy blames neither. The declared format string drawn here (valueDenominatorMatrix) is FICTIONAL and deliberately not one of the spec ii vocabulary members, so nothing on this page can be mistaken for a real vocabulary entry.
Annotation · not proposed UIThe omission route is closed here too, and that is now stated in the contract rather than inferred. Spec ii 3.10 as amended: on a clause whose answer format is unknown to the running version, BOTH routes fail closed, and the answer write AND the omission write refuse VOCAB_TYPE_INVALID, because an omission is still a write against a contract this version cannot validate. That is why both entry choices above are switched off rather than left to fail on save. This page's earlier draft raised the question; the spec answered it, and the drawing matches the answer.
Annotation · not proposed UIWhat identifies this answer (spec ii 6.4 and 3.8). A native answer is keyed by cycle, clause logical id, topic instance (null throughout I1), organization scope, and period. Native rows carry clauseLogicalId and do NOT populate disclosureId; they never pass through the legacy assignment and entry resolvers. The clause is resolved through the cycle's frozen edition set, so a question outside that edition set refuses with CLAUSE_NOT_IN_ASSEMBLY rather than rendering.
Annotation · not proposed UISECOND QUESTION FOR THE PM, about the copy rather than the mechanism. The panel tells the site manager to contact "your administrator", which is the wording the assignment fixed and the wording a site user understands. The actual remedy, though, is a newer app version, and in this phase deployment sits with the platform operator (Evercomm), not with the tenant's own administrator. So the tenant admin can only pass the message on. Two options: keep the current wording, which is honest about who the user should talk to first and hides the plumbing, or name the escalation explicitly ("your administrator, who will raise it with the platform operator"). Drawn with the shorter wording. The question code block below the panel exists so that whichever route is taken, the person on the receiving end gets what they need in one message.
Annotation · not proposed UIRole. Daniel Ong holds ENTRY access. Spec ii 6.2 gives the entry role read access to the two cycle catalog reads (GET /v1/reporting-cycles/:id/catalog and .../catalog/clauses/:logicalId) and 403 on every cycle mutation route; the full matrix is test 9.3. That is why no cycle action appears on this page. The application shell around the page stands in for existing NxStart chrome and is drawn identically on all twelve pages of this wireframe set so the surfaces can be compared; which menu items an entry-role user actually sees is existing product behavior this wireframe set does not restate, and it is not the mechanism that stops the write. The server is.